콘텐츠 본문
논문 국내 국내전문학술지(KCI급) 지열원 열펌프 시스템의 에너지 생산량 모니터링 신뢰도 향상 방안 연구
- 학술지 구분 국내전문학술지(KCI급)
- 게재년월 2019-06
- 저자명 도성록,강신형,이광호,최종민
- 학술지명 한국지열수열에너지학회 논문집
- 발행처명 한국지열수열에너지학회
- 발행국가 국내
- 논문언어 한국어
- 전체저자수 4
- 논문 다운로드 링크(외부) http://www.riss.kr/search/detail/DetailView.do?p_mat_type=1a0202e37d52c72d&control_no=347d86d98ddf387de9810257f7042666
논문 초록 (Abstract)
In this study, the present regulation of heat metering for the ground source heat pump was investigated.The ground source heat pump has been adopting the heat metering system used in the district heating system for estimating the heating and cooling energy production amount. The accuracy of the present heat metering systems for a water to water ground source heat pump is low, because the system for district heating has a relatively high temperature range comparing with the ground source heat pump operating conditions. Even though the heat amount for the building side should be measured, the heat absorption and extraction amount from or to the ground was measured for the water to air ground source heat pump due to the difficulty of estimating the air side heating and cooling capacity in the present regulation. It is highly recommended to validate the heat metering system to have reliability for the ground source heat pump and develop the system to be applicable water to air ground source heat pump.